Mu programs are sequences of fn
and type
definitions.
Define functions with the fn
keyword. For example:
fn foo arg1: int, arg2: int -> _/eax: boolean
Functions contain {}
blocks, var
declarations, primitive statements and
calls to other functions. Only {}
blocks can nest. Primitive statements and
function calls look similar:
out1, out2, out3, ... <- operation inout1, inout2, inout3, ...
They can take any number of inouts and outputs, including 0. Statements
with 0 outputs also drop the <-
.
Inouts can be either variables in memory, variables in registers, or literal constants (either integers or string literals that get replaced with constant addresses). Outputs are always variables in registers.
Inouts in memory can be either inputs or outputs (if they’re addresses being written to). Hence the name.
Primitives usually require their inouts to be in specific combinations of memory and register. They can’t handle more than one inout in memory. User-defined functions are flexible.
Primitives can often write to arbitrary output registers. User-defined
functions, however, require rigidly specified output registers. Notice how the
definition of foo
above writes to eax
.
A function’s header names its inouts, but not its outputs (hence the _
above).
All Mu programs must define at least one function: main
. That’s where they
begin executing instructions.
Declare local variables in a function using the var
keyword. As shown above,
all variable declarations should specify a type after a :
.
You can declare local variables in either registers or memory (the stack
segment). So a var
statement has two forms:
var x/eax: int <- copy 0
defines x
which
lives in eax
.var x: int
defines x
on the stack.Variables in registers must be initialized. Variables on the stack are implicitly zeroed out.
Variables exist only within the {}
block they’re defined in. Space allocated
to them on the stack is reclaimed after execution leaves the block. Registers
restore whatever variable was using them in the outer block.
It is perfectly ok to reuse a register for a new variable. Even in a single block (though you permanently lose the old variable then).
Variables can be in six 32-bit general-purpose registers of the x86 processor.
Most functions return results in eax
by convention. In practice, it ends up
churning through variables pretty quickly.
You can store several types in these registers:
There’s one 32-bit type you cannot store in these registers:
It instead uses eight separate 32-bit registers: xmm0, xmm1, …, xmm7
Types that require more than 32 bits (4 bytes) cannot be stored in registers:
type
keywordT
here can be any type, including combinations of types. For example:
Other miscellaneous restrictions:
byte
variables must be either in registers or on the heap, never local
variables on the stack.addr
variables can never “escape” a function either by being returned or
by being written to a memory location. When you need that sort of thing,
use a handle
instead.We’ll now survey a long list of statement forms that operate on 32-bit types. Most of these are primitives, but some are also implemented as functions (which have slightly different rules as mentioned up top). Most instructions with multiple args require types to match. Various operations have other restrictions which we’ll note below, using the following notation:
var/reg
indicates a variable in some register. Where we require a
variable in a specific register, we’ll mention it explicitly. E.g.
var/eax
.var/xreg
indicates a variable in some floating-point register xmm_
.var
without a reg
indicates either a variable on the stack, or
dereferencing a variable in a (non-floating-point) register: *var/reg
.var: type
indicates a variable that must satisfy some type constraint.n
indicates a literal integer. There are no floating-point literals.These instructions work with variables of any 32-bit type except byte
and
float
.
var/reg <- copy var2/reg2
copy-to var1, var2/reg
var/reg <- copy var2
var/reg <- copy n
copy-to var, n
Byte variables have their own instructions:
var/reg <- copy-byte var2/reg2
var/reg <- copy-byte *var2/reg2 # var2 must have type (addr byte)
copy-byte-to *var1/reg1, var2/reg2 # var1 must have type (addr byte)
Floating point variables can be copied as well, but only to or from
floating-point registers xmm_
.
var/xreg <- copy var2/xreg2
copy-to var1, var2/xreg
var/xreg <- copy var2
var/xreg <- copy *var2/reg2 # var2 must have type (addr byte) and live in a general-purpose register
There’s no way to copy a literal to a floating-point register. However, there’s a few ways to convert non-float values in general-purpose registers.
var/xreg <- convert var2/reg2
var/xreg <- convert var2
var/xreg <- convert *var2/reg2
Correspondingly, there are ways to convert floats into integers, with and without rounding.
var/reg <- convert var2/xreg2
var/reg <- convert var2
var/reg <- convert *var2/reg2
var/reg <- truncate var2/xreg2
var/reg <- truncate var2
var/reg <- truncate *var2/reg2
Still, the absence of fractional literals is an annoyance. Mu provides some helpers to mitigate it somewhat:
result/xmm0 <- rational numerator: int, denominator: int
fill-in-rational out: (addr float), numerator: int, denominator: int
These are functions, so the inouts have fewer restrictions while the outputs
have more. The inouts can be registers, or memory, or even literals. The
output for rational
must be in register xmm0
.
Work with variables of any 32-bit type. addr
variables can only be compared
to 0.
compare var1, var2/reg
compare var1/reg, var2
compare var/eax, n
compare var, n
Floating-point numbers cannot be compared to literals, and the register must come first.
compare var1/xreg1, var2/xreg2
compare var1/xreg1, var2
Immediately after a compare
instruction you can branch on its result. For
example:
break-if-=
This instruction will jump to after the enclosing {}
block if the previous
compare
detected equality. Here’s the list of conditional and unconditional
break
instructions:
break
break-if-=
break-if-!=
break-if-<
break-if->
break-if-<=
break-if->=
Similarly, you can jump back to the start of the enclosing {}
block with
loop
. Here’s the list of loop
instructions.
loop
loop-if-=
loop-if-!=
loop-if-<
loop-if->
loop-if-<=
loop-if->=
Additionally, there are special variants for comparing addr
and float
values, which results in the following comprehensive list of jumps:
break
break-if-=
break-if-!=
break-if-< break-if-addr< break-if-float<
break-if-> break-if-addr> break-if-float>
break-if-<= break-if-addr<= break-if-float<=
break-if->= break-if-addr>= break-if-float>=
loop
loop-if-=
loop-if-!=
loop-if-< loop-if-addr< loop-if-float<
loop-if-> loop-if-addr> loop-if-float>
loop-if-<= loop-if-addr<= loop-if-float<=
loop-if->= loop-if-addr>= loop-if-float>=
One final property all these jump instructions share: they can take an optional block name to jump to. For example:
a: {
...
break a #----------|
... # |
} # <--|
a: { # <--|
... # |
b: { # |
... # |
loop a #----------|
...
}
...
}
However, there’s no way to jump to a block that doesn’t contain the loop
or
break
instruction.
These instructions require variables of non-addr
, non-float
types.
Add:
var1/reg1 <- add var2/reg2
var1/reg <- add var2
add-to var1, var2/reg # var1 += var2
var/reg <- add n
add-to var, n
Subtract:
var1/reg1 <- subtract var2/reg2
var1/reg <- subtract var2
subtract-from var1, var2/reg # var1 -= var2
var/reg <- subtract n
subtract-from var, n
Add one:
var/reg <- increment
increment var
Subtract one:
var/reg <- decrement
decrement var
Multiply:
var1/reg <- multiply var2
The result of a multiply must be a register.
Negate:
var/reg1 <- negate
negate var
Operations on float
variables include a few we’ve seen before and some new
ones. Notice here that we mostly use floating-point registers xmm_
, but
still use the general-purpose registers when dereferencing variables of type
(addr float)
.
var1/xreg <- add var2/xreg2
var1/xreg <- add var2
var1/xreg <- add *var2/reg2
var1/xreg <- subtract var2/xreg2
var1/xreg <- subtract var2
var1/xreg <- subtract *var2/reg2
var1/xreg <- multiply var2/xreg2
var1/xreg <- multiply var2
var1/xreg <- multiply *var2/reg2
var1/xreg <- divide var2/xreg2
var1/xreg <- divide var2
var1/xreg <- divide *var2/reg2
var1/xreg <- reciprocal var2/xreg2
var1/xreg <- reciprocal var2
var1/xreg <- reciprocal *var2/reg2
var1/xreg <- square-root var2/xreg2
var1/xreg <- square-root var2
var1/xreg <- square-root *var2/reg2
var1/xreg <- inverse-square-root var2/xreg2
var1/xreg <- inverse-square-root var2
var1/xreg <- inverse-square-root *var2/reg2
var1/xreg <- min var2/xreg2
var1/xreg <- min var2
var1/xreg <- min *var2/reg2
var1/xreg <- max var2/xreg2
var1/xreg <- max var2
var1/xreg <- max *var2/reg2
Two instructions in the above list are approximate. According to the Intel
manual, reciprocal
and inverse-square-root
go off the rails around the
fourth decimal place. If you need more precision, use
divide
separately.
These require variables of non-addr
, non-float
types.
And:
var1/reg1 <- and var2/reg2
var1/reg <- and var2
and-with var1, var2/reg
var/reg <- and n
and-with var, n
Or:
var1/reg1 <- or var2/reg2
var1/reg <- or var2
or-with var1, var2/reg
var/reg <- or n
or-with var, n
Not:
var1/reg1 <- not
not var
Xor:
var1/reg1 <- xor var2/reg2
var1/reg <- xor var2
xor-with var1, var2/reg
var/reg <- xor n
xor-with var, n
Shifts require variables of non-addr
, non-float
types.
var/reg <- shift-left n
var/reg <- shift-right n
var/reg <- shift-right-signed n
shift-left var, n
shift-right var, n
shift-right-signed var, n
Shifting bits left always inserts zeros on the right. Shifting bits right inserts zeros on the left by default. A signed shift right duplicates the leftmost bit, thereby preserving the sign of an integer.
These instructions work with any type T
. As before we use /reg
here to
indicate when a variable must live in a register. We also include type
constraints after a :
.
You can compute the address of any variable in memory (never in registers):
var1/reg: (addr T) <- address var2: T
As mentioned up top, addr
variables can never escape the function where
they’re computed. You can’t store them on the heap, or in compound types.
Think of them as short-lived things.
To manage long-lived addresses, allocate them on the heap.
allocate var: (addr handle T) # var can be in either register or memory
Handles can be copied and stored without restriction. However, they’re too
large to fit in a register. You also can’t access their payload directly, you
have to first convert them into a short-lived addr
using lookup.
var1/eax: (addr T) <- lookup var2: (handle T) # var2 in either register or memory
Since handles are large compound types, there’s a special helper for comparing them:
var/eax: boolean <- handle-equal? var1: (handle T), var2: (handle T)
Arrays are declared in two ways:
var x: (array int 3)
var x: (handle array int)
var x-ah/eax: (addr handle array int) <- address x
populate x-ah, 8
The 8
here can also be an int in a register or memory. (The -ah
is a
common variable naming convention and stands for “address of a handle”.
Essential for allocating long-lived data on the heap.)
You can compute the length of an array, though you’ll need an addr
to do so:
var/reg: int <- length arr/reg: (addr array T)
To read from or write to an array, use index
to first obtain an address to
read from or modify:
var/reg: (addr T) <- index arr/reg: (addr array T), n
var/reg: (addr T) <- index arr: (array T len), n
Like our notation of n
, len
here is required to be a literal.
The index requested can also be a variable in a register, with one caveat:
var/reg: (addr T) <- index arr/reg: (addr array T), idx/reg: int
var/reg: (addr T) <- index arr: (array T len), idx/reg: int
The caveat: the size of T must be 1, 2, 4 or 8 bytes. For other sizes of T
you’ll need to split up the work, performing a compute-offset
before the
index
.
var/reg: (offset T) <- compute-offset arr: (addr array T), idx/reg: int # arr can be in reg or mem
var/reg: (offset T) <- compute-offset arr: (addr array T), idx: int # arr can be in reg or mem
The result of a compute-offset
statement can be passed to index
:
var/reg: (addr T) <- index arr/reg: (addr array T), idx/reg: (offset T)
A common use for arrays is as buffers. Save a few items to a scratch space and
then process them. This pattern is so common (we use it in files) that there’s
special support for it with a built-in type: stream
.
Streams are like arrays in many ways. You can initialize them with a length on the stack:
var x: (stream int 3)
You can also populate them on the heap:
var x: (handle stream int)
var x-ah/eax: (addr handle stream int) <- address x
populate-stream x-ah, 8
However, streams don’t provide random access with an index
instruction.
Instead, you write to them sequentially, and read back what you wrote.
read-from-stream s: (addr stream T), out: (addr T)
write-to-stream s: (addr stream T), in: (addr T)
Streams of bytes are particularly common for managing Unicode text, and there are a few functions to help with them:
write s: (addr stream byte), u: (addr array byte) # write u to s, abort if full
overflow?/eax: boolean <- try-write s: (addr stream byte), u: (addr array byte)
write-stream dest: (addr stream byte), src: (addr stream byte)
# bytes
append-byte s: (addr stream byte), var: int # write lower byte of var
var/eax: byte <- read-byte s: (addr stream byte)
# 32-bit code-point-utf8s encoded in UTF-8
write-code-point-utf8 out: (addr stream byte), g: code-point-utf8
g/eax: code-point-utf8 <- read-code-point-utf8 in: (addr stream byte)
You can check if a stream is empty or full:
var/eax: boolean <- stream-empty? s: (addr stream)
var/eax: boolean <- stream-full? s: (addr stream)
You can clear streams:
clear-stream f: (addr stream T)
You can also rewind them to reread their contents:
rewind-stream f: (addr stream T)
Primitive types can be combined together using the type
keyword. For
example:
type point {
x: int
y: int
}
Mu programs are sequences of just fn
and type
definitions.
Compound types can’t include addr
types for safety reasons (use handle
instead,
which is described below). They also can’t currently include array
, stream
or byte
types. Since arrays and streams carry their size with them, supporting
them in compound types complicates variable initialization. Instead of
defining them inline in a type definition, define a handle
to them. Bytes
shouldn’t be used for anything but UTF-8 strings.
To access within a compound type, use the get
instruction. There are two
forms. You need either a variable of the type itself (say T
) in memory, or a
variable of type (addr T)
in a register.
var/reg: (addr T_f) <- get var/reg: (addr T), f
var/reg: (addr T_f) <- get var: T, f
The f
here is the field name from the type
definition, and its type T_f
must match the type of f
in the type
definition. For example, some legal
instructions for the definition of point
above:
var a/eax: (addr int) <- get p, x
var a/eax: (addr int) <- get p, y
You can clear compound types using the clear-object
function:
clear-object var: (addr T)
You can shallow-copy compound types using the copy-object
function:
copy-object src: (addr T), dest: (addr T)